ru.unix.bsd- RU.UNIX.BSD ------------------------------------------------------------------ From : ‘«св®ў Ђ«ҐЄб ¤а 2:5020/400 23 Dec 2002 17:43:53 To : All Subject : Проблеммы с Mylex Acceleraid 352 -------------------------------------------------------------------------------- Привет ALL! Есть сервер на базе шасси intel sc5000, мать Intel STL2. Диски цепляются на Mylex Acceleraid 352 через интеловский hotswap controller ESG-SHV SCA HSBP M14. Hа сервере крутится FreeBSD 4.7 Stable. Проблемма в том, что при загрузке ядро фри не видит hotswap контролеры. Хотя все устройства в ядро вкомпилированы статически, т.е. при загрузке ядро говорит: acd0: CDROM <ASUS CD-S500/A> at ata0-master PIO4 mly0: physical device 1:6 gone mly0: physical device 0:6 gone mly0: enclosure 6 unit 0 access offline mly0: enclosure 6 unit 0 access offline mly0: physical device 0:6 gone mly0: physical device 1:6 gone mly0: physical device 0:6 gone mly0: physical device 1:6 gone mly0: physical device 0:6 gone mly0: physical device 1:6 gone mly0: physical device 0:6 gone mly0: physical device 1:6 gone da0 at mly0 bus 2 target 0 lun 0 da0: <RAID 5 online > Fixed Direct Access SCSI-3 device da0: 135.168MB/s transfers da0: 315252MB (645636096 512 byte sectors: 255H 63S/T 40188C) Mounting root from ufs:/dev/da0s1a Устройства device 0:6 и device 1:6 есть hotswap контроллеры на scsi шине 0 и 1, соответственно, и со scsi id 6. Если после загрузки пересканировать scsi шины то всё появляется: #camcontrol rescan all re-scan of bus 0 was successful mly0: physical device 0:6 sense data received mly0: sense key 5 asc 24 ascq 00 mly0: info 00000000 csi 00000000 ses0 at mly0 bus 0 target 6 lun 0 ses0: <ESG-SHV SCA HSBP M14 0.03> Fixed Processor SCSI-2 device ses0: 135.168MB/s transfers ses0: SAF-TE Compliant Device re-scan of bus 1 was successful mly0: physical device 1:6 sense data received mly0: sense key 5 asc 24 ascq 00 mly0: info 00000000 csi 00000000 ses1 at mly0 bus 1 target 6 lun 0 ses1: <ESG-SHV SCA HSBP M14 0.03> Fixed Processor SCSI-2 device ses1: 135.168MB/s transfers ses1: SAF-TE Compliant Device re-scan of bus 2 was successful re-scan of bus 3 was successful Ядро собрано со следующими опциями, касательно scsi: ## RAID controllers interfaced to the SCSI subsystem device mly0 # SCSI peripherals options SES_ENABLE_PASSTHROUGH device scbus0 at mly0 bus0 device scbus1 at mly0 bus1 device scbus2 at mly0 bus2 device ses0 at scbus0 target 6 unit 0 device ses1 at scbus1 target 6 unit 0 device da0 at scbus2 target 0 unit 0 device pass Вопрос в том как правильно собрать ядро, что-бы hotswap контроллеры определялись при загрузке системы? Очень надеюсь на помощь коллективного разума ;) -- C уважением, Слётов Александр. --- ifmail v.2.15dev5 * Origin: Demos online service (2:5020/400) Вернуться к списку тем, сортированных по: возрастание даты уменьшение даты тема автор
Архивное /ru.unix.bsd/6577dcdcf383.html, оценка из 5, голосов 10
|